windows-server-2003 – 从Windows识别HP阵列逻辑驱动器
可能很简单,但我正在尝试确定HP服务器阵列中的哪个逻辑驱动器与
Windows Server 2003中提供的特定磁盘相关.
所以我有一台带有两个RAID控制器的Proliant DL580 G5服务器.有问题的控制器是一个Smart Array P400,它有8个磁盘,分为4个阵列(A,B,C,D),每个阵列都有一个RAID 1逻辑驱动器.服务器报告其中一个逻辑驱动器上的磁盘故障,我想在更换故障磁盘之前备份文件. 我认为这将是一项简单的任务,证明有点痛苦.如何识别哪个窗口“磁盘”与RAID阵列中的每个逻辑驱动器相关?我在diskmgmt.msc中找不到与ACU中的属性相关的任何属性.虽然我知道它是哪一个,但我不能确定. 提前致谢…
您是否安装了HP管理实用程序?下载
ProLiant Support Pack for Windows 2003(或
64-bit variant).
这将有助于提供系统的一般管理和健康监测.至少,您可以通过安装ProLiant Support Pack的Array Configuration Utility CLI (command line interface)组件来获取您正在寻找的信息. 运行快捷命令如ctrl all show config detail将生成大量的控制器,阵列和磁盘信息;包括挂载点.您还将看到哪些驱动器分配给哪个RAID 1对以及每个逻辑驱动器的总体运行状况.根据此信息,您应该能够无缝地更换发生故障的驱动器,但请确保先检查输出. HP Array Configuration Utility CLI 8.60-8.0 Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: PH7AMW5213 Cache Serial Number: PA82C0H9SVC7O6 RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev D Firmware Version: 7.18 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 256 MB No-Battery Write Cache: Enabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001032313320202020200001 Disk Name: .PhysicalDrive0 Mount Points: C: 136.7 GB Logical Drive Label: A240AB6BPH7AMW5213 E1C6 Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1,SAS,146 GB,OK) Mirror Group 1: physicaldrive 1I:1:2 (port 1I:box 1:bay 2,OK) physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPD1 Serial Number: BS01P7900S6P0738 Model: HP DG146A3516 PHY Count: 1 PHY Transfer Rate: 3.0GBPS physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPD1 Serial Number: BS01P7900PY80737 Model: HP DG146A3516 PHY Count: 1 PHY Transfer Rate: Unknown (编辑:李大同) 【声明】本站内容均来自网络,其相关言论仅代表作者个人观点,不代表本站立场。若无意侵犯到您的权利,请及时与联系站长删除相关内容! |
- 用于Windows的Git bash不提示输入密码
- windows-phone-7 – ListBox数据虚拟化没有生效
- 常用Windows命令、常用 Cmd命令
- windows-phone-7 – 市场应用程序图标用法
- windows-vista – UAC对开发人员有多重要?
- 带有资源字典的wpf类库
- windows – 追踪哪个进程/程序导致Kerberos预身份验证错误(
- 02、Windows Server 2003域账户管理(04)
- Windows 7 – 如何在Windows 7任务调度程序中使用Messagebo
- windows-phone-7 – 为什么我在尝试使用HttpWebRequest时会